Flow Measurement and Control Solutions

Engineered flow measurement and control to optimize performance, protect assets, and keep your operations running within spec

Description
Specifications

Parshall Weirs

Inches

MM

Minimum

Maximum

1

25.40

0.12

5.31

2

50.80

0.19

12.25

3

76.20

0.25

32.00

6

152.40

1.82

87.00

9

228.60

2.58

176.70

12

304.80

9.21

462.80

18

457.20

14.13

696.50

24

609.60

18.67

937.07

30

762.00

23.08

1,180.36

48

1,219.20

35.72

1,923.44

60

1,524.00

62.77

2,424.00

72

1,828.80

74.44

2,931.11

96

2,438.40

130.78

3,949.94

Palmer-Bowlus Channels

Inches

MM

Minimum

Maximum

4

0.10

0.122

3.435

6

0.15

0.172

14.497

8

0.20

0.216

19.537

10

0.25

0.261

31.694

12

0.30

0.463

47.469

15

0.38

0.762

76.774

18

0.46

1.430

130.660

21

0.53

1.894

287.035

24

0.61

2.713

357.437

27

0.69

3.560

370.560

30

0.76

3.707

467.725

36

0.91

6.967

489.245

42

1.07

11.022

1,085.529

48

1.22

15.061

1,516.120